센터장비

Metabolic cage
  • Device name
    Metabolic cage
  • Model
    CI BUS SLAVE
    CI-BUS Serial Interface
  • Manufacturer
    Columbus Instruments
  • Usage
    Measurement of energy balance
  • Strengths
    Conducts a real-time analysis of food intake, energy expenditure, tidal volume, temperature changes, etc., under the same conditions. Can secure high repeatability and reliability.
MRI/MRS
  • Device name
    MRI/MRS
  • Model
    Biospec 94/20 USR
  • Manufacturer
    Bruker BioSpin
  • Usage
    Non-invasive in vivo analysis of whole-body drug distribution
  • Specifications
    Magnet : 9.4 Tesla
    Bore size : 200 mm, horizontal
  • Strengths
    Features the country’s largest magnetic field intensity
    High image resolution and zero signal-to-noise ratio
Treadmill
  • Device name
    Treadmill
  • Model
    4Z528B
  • Manufacturer
    Columbus Instruments
  • Usage
    Measure motor ability
  • Strengths
    Performs an accurate real-time measurement of motor ability, tidal volume during exercise, and energy expenditure
Mini-spec
  • Device name
    Mini-spec
  • Model
    LF90II
  • Manufacturer
    Bruker BioSpin
  • UsageMeasure obesity levels
  • Specifications
    2nd-generation BCA analyzer for mice and rats
  • Strengths
    Can measure body fat content in living animals within 90 seconds.
    Can conduct a significant evaluation with a small number of animals.
β counter
  • Device name
    β counter
  • Model
    1450LSC
  • Manufacturer
    Perkin Elmer
  • Usage
    Measure radioisotopes (plate type)
  • Specifications
    Time-Resolved (TR-LSC) method
  • Strengths
    Various radioisotopes are available (3H, 14C, 32P, 33P, 35S, 51Cr ,125I). PMT location is automatically adjusted to containers of samples. Up to 12 samples can be simultaneously measured.
γ counter
  • Device name
    γ counter
  • Model
    Wizard2
  • Manufacturer
    Perkin Elmer
  • Usage
    Measure radioisotope volume
  • Specifications
    Radio library: 51 kinds
    Max. count rate: 10 million DPM for 125I
  • Strengths
    A detector is located at the bottom of samples, producing the best measurement results. With the input of radioisotope information, radioisotopes can be measured by nucleus type with the best conditions.
β counter
  • Device name
    β counter
  • Model
    Tri-card 3110TR
  • Manufacturer
    Perkin Elmer
  • UsageMeasure radioisotopes (vial type)
  • Specifications
    Efficiency & (E2/B): 3H 60%, 180/ 14C 5%, 380
    Background: 3H 17.3 CPM / 14C 24.3 CPM
  • Strengths
    Can measure even minute α/β radioactive activity.
Autoclave
  • Device name
    Autoclave
  • Model
    VSSRZ-O09
  • Manufacturer
    SAKURA
  • UsageSterilize experimental apparatuses and reagents
  • Strengths
    The device not only offers a high level of sterilization, but it is also easy to use, convenient and efficient in animal facilities and laboratories in everything from cage handling to operation and repair.
Metabolic cage
  • Device name
    LC/MS/MS
  • Model
    4000Q Trap
  • Manufacturer
    Applied Biosystems
  • Usage
    Analyze tissue lipid metabolites
  • Specifications
    Ion source: TurboV source (ESI/APCl)
    Mass range (m/z): 5-2800
  • Strengths
    High quantitative sensitivity
    High specific scan function
    Can analyze a small amount of metabolites up to 0.1 pmol.
Glucose Analzer
  • Device name
    Glucose Analzer
  • Model
    GM9
  • Manufacturer
    Analox
  • Usage
    Measure blood glucose
  • Specifications
    Method: Enzymatic oxygen rate
    Sensor: Clark-type amperometric oxygen electrode
  • Strengths
    Both whole blood and plasmas can be used.
    The test result can be confirmed with a small volume of samples within a few seconds
GC/MS
  • Device name
    GC/MS
  • Model
    7890A
  • Manufacturer
    Agilent technologies
  • Usage
    Analyze tissue and blood fatty acids
  • Specifications
    TAD : Triple-axis detector
  • Strengths
    Can move only target ions to XYZ and detect them.
    Can perform scanning and analytical functions with the Auto SIM feature
Autometic biochemical Analyzer
  • Device name
    Autometic biochemical Analyzer
  • Model
    COBAS C111
  • Manufacturer
    ROCHE
  • Usage
    Analysis of lipid profiles and biochemical factors
  • Specifications
    50 photometric
    27 bottle positions
    3 ISE tests, 10 profiles
  • Strengths
    Can conduct ISE integrated examination.
    Can ensure enhanced reagent stability and spatial efficiency.
    Can perform 14 items at a time
DCA vantage analyzer
  • Device name
    DCA vantage analyzer
  • Model
    DCA vantage analyze
  • Manufacturer
    Siemens
  • Usage
    Measure Hemoglobin A1c
  • Specifications
    HbA1c : 2.5-14% (whole blood)
    LIAI(Latex immunoagglutination inhibition)
  • Strengths
    Ensures high-sense measurement with mice.
    Can measure with 1ul of whole blood.
Microcal
  • Device name
    Microcal
  • Model
    ITC200
  • Manufacturer
    GE health
  • Usage
    Can measure a combination of new drug and targets, and the interaction of proteins
  • Strengths
    Can complete thermodynamic profiles with one-time experiment.
    Can directly measure binding specificity and stoichiometry
Tissue Lyser
  • Device name
    Tissue Lyser
  • Model
    20-747-008
  • Manufacturer
    QIAGEN
  • UsageTissue fragmentation
  • Strengths
    Can homogenize up to 192 samples within 2 minutes.
    Can confirm repeatable results in tissues that are difficult to homogenate.
    No cross-contamination.
ELISA reader
  • Device name
    ELISA reader
  • Model
    Versamax
  • Manufacturer
    Molecular devices
  • Usage
    Quantitative analysis of insulin and free fatty acids
  • Specifications
    Wavelength Range: 340-850 nm
    Photometric Range: 0.000 to 4.000 OD
    Temperature Range: Ambient + 4 °C–45 °C
  • Strengths
    Does not require the purchase or replacement of filters.
    Can simultaneously select two wavelengths and measure absorbance.
    Can mix samples in the well with a programmed Automix feature.
Centrifuge
  • Device name
    Centrifuge
  • Model
    R5810
  • Manufacturer
    Effendorf
  • Usage
    Centrifugation of the samples
  • Specifications
    14,000rpm (RCF 20,800 ×g) temperature range : -9 ~ 40°C
  • Strengths
    Can quickly cool down to 4°C (within 15 minutes) at room temperature
    Intelligent rotor speed recognition prevents overspeeding
100,000 Ultra Centrifuge
  • Device name
    100,000 Ultra Centrifuge
  • Model
    Optima L-100XP
  • Manufacturer
    Beckman Coulter
  • Usage
    Centrifugation of cell/tissue homogenates
  • Specifications
    Max. speed : 100,000 rpm
    Max. force : 802,400 g
    Refrigeration system : Thermoelectric - no CFCs, ODCs
15,000 High centrifuge
  • Device name
    15,000 High centrifuge
  • Model
    Avanti J-E
  • Manufacturer
    Berkman Coulter
  • Usage
    Centrifugation of cell/tissue homogenates
  • Specifications
    Speed Range 300 to 21,000 rpm
    Set Time to 99 hr 59 min or continuous (hold)
QRT-PCR
  • Device name
    QRT-PCR
  • Model
    AB17300
  • Manufacturer
    Applied Biosystems
  • Usage
    Quantitative analysis of gene expression
  • Specifications
    Tungsten-halogen lamp excitation source. SYBR® Green I, FAM™, VIC™, JOE™, NED™, TAMRA™, ROX™
  • Strengths
    Can produce accurate, highly reliable results within a minimum time.
    Applicable to diverse experiments, thanks to its ability to sense diverse colors.
Chemi-Doc
  • Device name
    Chemi-Doc
  • Model
    LAS-400
  • Manufacturer
    Fuji film
  • Usage
    Analysis of immunoblots and DNA gels
  • Specifications
    six interchangeable light sources
    five position filter turret
    3.2-megapixel Sepper CCD imaging chip
  • Strengths
    Can analyze luminous images without x-ray film development.
    Its quantitative analysis program ensures immediate results
AKTA FPLC
  • Device name
    AKTA FPLC
  • Model
    UPC 100
  • Manufacturer
    AKTA Purifier
  • Usage
    Separate lipoproteins and proteins
  • Specifications
    modular liquid chromatography ststems
    Flow rates of 0.001 to 10ml/min at pressures of 0 to 25MPa
  • Strengths
    Can shorten sample loading time and remove contamination